Search results for "implant stability"
showing 10 items of 20 documents
Efficacy of the laser at low intensity on primary burning oral syndrome: a systematic review.
2020
Background Primary burning mouth syndrome (BMS) is a chronic clinical condition of idiopathic mainly characterized by pain and a burning sensation in the oral cavity. The application of laser at low intensity therapy is a treatment option. This systematic review evaluated the efficacy of laser therapy in treating symptoms of burning mouth syndrome. Material and Methods The study was formulated according to the PRISMA and Cochrane guidelines. Seven databases were used as primary sources of research. Only randomized controlled clinical trials were included. The efficacy of the therapy was estimated comparing the values of the visual and numerical scales of pain before and after laser treatmen…
Comparison of implant primary stability between maxillary edentulous ridges receiving intramembranous origin block grafts
2012
Purpose: The purposes of the present study were: to compare the resonance frequency analysis (RFA) values of implant placed in either ramus or calvaria block grafts; and to determine if implant diameter influences RFA implant stability quotient (ISQ) value. Material and Methods: This was a retrospective study that included 16 consecutives healthy patients treated with autogenous onlay block grafts for horizontal bone reconstruction in maxilla. Ten ramus and ten calvaria block graft treated patients were selected and compared. Results: Totally, 59 implants were placed, 35 (59.3%) were placed on the calvaria bone grafts and the remaining 24 (40.7%) were on the ramus bone graft. Of all the imp…
Immediate implants following tooth extraction. A systematic review
2012
Objectives: The aim of this article is to review the current state of immediate implants, with their pros and contras, and the clinical indications and contraindications. Material and Methods: An exhaustive literature search has been carried out in the COCHRANE library and MEDLINE electronic databases from 2004 to November 2009. Randomized clinical trials and clinical trials focused on single implants placed in fresh extraction sockets were included and compared. A meta-analysis could not be performed due to heterogeneity of the data. Results: Twenty studies out of 135 articles from the initial search were finally included, which summed up a total of 1139 immediate implants with at least a …
On the use of the electromechanical impedance technique for the assessment of dental implant stability: Modeling and experimentation
2014
We propose the electromechanical impedance technique to monitor the stability of dental implants. The technique consists of bonding one wafer-type piezoelectric transducers to the implant system. When subjected to an electric field, the transducer induces structural excitations which, in turn, affect the transducer’s electrical admittance. The hypothesis is that the health of the bone surrounding the implant affects the sensor’s admittance. A three-dimensional finite element model of a transducer bonded to the abutment of a dental implant placed in a host bone site was created to simulate the progress of the tissue healing that occurs after surgery. The healing was modeled by changing the …
Sensitivity and Specificity of Stability Criteria for Immediately Loaded Splinted Maxillary Implants
2014
Background To assess the suitability of dental implants for immediate loading, primary stability is usually evaluated intraoperatively. Purpose This retrospective study aimed to assess the suitability of three stability parameters – namely, insertion torque (IT), implant stability quotient (ISQ; measured by resonance frequency analysis), and Periotest (PT) values – as potential predictors for the risk of nonosseointegration of immediately loaded splinted implants. The stability parameters were routinely collected under immediate loading. Materials and Methods Nineteen patients with 11 edentulous and 8 partially edentulous maxillae were treated with 105 dental implants, which were immediatel…
Electromechanical Impedance Method to Assess the Stability of Dental Implants
2017
In this paper we illustrate the application of the electromechanical impedance (EMI) technique, popular in structural health monitoring, to assess the stability of dental implants. The technique consists of bonding a piezoelectric transducer to the element to be monitored. When subjected to an electric field, the transducer induces low to high frequency structural excitations which, in turn, affect the transducer's electrical admittance. As the structural vibrations depend on the mechanical impedance of the host structure (in this case the implant secured to the jaw), the measurement of the PZT's admittance can infer the progress of the osseointegration process. In the study presented in th…
Secondary implant stability outcome of immediate versus late placed variable-thread implants in the maxilla. A retrospective cohort study
2017
BACKGROUND The healing of xenograft augmentated intra-alveolar gaps following immediate implant placement (IMIP) after tooth extraction is likely to differ in time and density compared to the native bone part that directly contacts the implant. MATERIAL AND METHODS Secondary implant stability (SIS) data recorded 2-3 months following a late implant placement protocol (LIP) (n= 43) and 6-8 months following an immediate implant placement protocol (IMIP) (n=33) of variable-thread implants (Nobel Active™) in the maxilla were retrospectively collected from files of 63 patients (42 females, 21 males). Statistical analysis was performed using a generalized estimating equation model (GEE). Data spli…
Biomechanical evaluation of oversized drilling technique on primary implant stability measured by insertion torque and resonance frequency analysis
2015
Background This study evaluated the influence of implant site preparation depth on primary stability measured by insertion torque and resonance frequency analysis (RFA). Material and Methods Thirty-two implant sites were prepared in eight veal rib blocks. Sixteen sites were prepared using the conventional drilling sequence recommended by the manufacturer to a working depth of 10mm. The remaining 16 sites were prepared using an oversize drilling technique (overpreparation) to a working depth of 12mm. Bone density was determined using cone beam computerized tomography (CBCT). The implants were placed and primary stability was measured by two methods: insertion torque (Ncm), and RFA (implant s…
Predictability of the resonance frequency analysis in the survival of dental implants placed in the anterior non-atrophied edentulous mandible.
2010
Background: Dental primary implant stability is considered essential in the success of the osseointegration process. The recent advent of the resonance frequency analysis (RFA) seems to effectively measure primary implant stability, although its relationship with implant survival has to be further established. Patients and Methods: Seventy patients with complete mandibular edentulism underwent dental implant rehabilitation by means of the placement of 68 dental implants within the interforaminal region and subsequent placement of an overdenture. Primary implant stability was measured by means of RFA and it was expressed in terms of imPrimary implant stability was measured by means of RFA an…
Repeatability of the resonance frequency analysis values in implants with a new technology
2019
Background Assess the reliability (by means of reproducibility and repeatability) of the PenguinRFA system, analyse the ISQ values of different implant types and correlate the ISQ with the insertion torque during the placement of the implant. Material and Methods 120 rough surface implants were placed in bovine bone (type II and III). The implants were divided into groups, according to its design. Once the implants were in place, the exact insertion torque was registered. Then, primary stability was measured by means of the resonance frequency analysis with the PenguinRFA and the Osstell ISQ devices. In each implant two transducers of each device were used. Three measurements were obtained …